The simulation offers two ways to set the heat pump's electricity consumption: manually or from the seasonal performance factor (SPF).
Manual entry
If you work with standard values or need a quick simulation, enter the yearly electricity consumption under Heat pump electricity consumption (yearly, kWh). autarc spreads it over the year using the Usage pattern and bills it at the heat pump's tariff.
Calculating electricity consumption with the seasonal performance factor (SPF)
Switch on Use seasonal performance factor (SPF). autarc then calculates the electricity consumption from the heat load, the full load hours and the SPF:
Heat demand = heat load × full load hours Heat pump electricity consumption = heat demand / SPF
Heat load: you edit the heat load in the
Heating plannerunderTechnical Parameters:Directly enter,Consumption-basedfrom previous consumption data, orRoom-basedusing method B. TheHeating plannerlink in the simulation takes you straight there. In the UK, the link is calledHeat pump details.Full load hours: autarc determines them automatically from the postcode of the project address and the design outside temperature.
SPF: enter the SPF under
Seasonal performance factor (SPF). If a heat pump is selected underHeat pump model, autarc prefills the field with its COP at A2/W35. The COP is often close to the SPF but doesn't replace an SPF calculation. For projects in Germany, theSPF calculatorlink opens the SPF calculator of the German Heat Pump Association.